Our Product Range
|
We are offering durable range of Solvent Recovery System. Our products are developed with fine quality materials and are reputed for their optimum performance and usage. They are customized and developed as desired by customers’ and are offered at market leading rates. Our products are adequately tested on various quality parameters.
|
| | Solvent Recovery 30 LTR  | Special Features Flexo 30L-RHB Solvent Recovery Unit For photopolymer flexo plates
A. General description: 30L-RHBis designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.
B. Technical information: Recovery volume :30 liters Power consume : 220V 3. 65kw Diathermic oil : 20 KG Machine dimension : 960x 610x 9400 mm Main body Recovery rate : 85%
C. Operating steps:After opening the crate, plug in 220 V power, and connect the ground (earth). Open the lid and fill the tank up to the level with solvent to be recovered (30 L).Close the lid and tighten it.Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1). Set up the thermostat (18) for example for Perc. Is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure (3) high at 0. 03 Mpa / low at 0. 01mpa, and steam cooling fan thermostat (11) at 40 degree C. Turn on the power switch (15) , steam cooling switch (16) , heater switch (17) and vacuum pump switch (12). If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).
D. Important:Install the unit in a wide and ventilated place. Disconnect electric power before doing any action.No taking off the control panel. Change the diathermic oil every 1000 working hours. No filling the solvent container up over the level (30 liters). Remove the waste after every recovery process.
Other Information
- Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Western Union
- Minimum Order Quantity: 1 Set/Sets
- Port of Dispatch: Ahmedabad
- Production Capacity: 100
- Delivery Time: 4 Weeks
- Packaging Details: Wooden Crates, Export Packaging
| Solvent Recovery 60 LTR  | Special Features Flexo 60L-RHB Solvent Recovery Unit For photopolymer flexo plates
A. General description: 60L-RHBis designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.
B. Technical information: Recovery volume: 60 liters Power consume: 220V 4. 65kw Diathermic oil : 28 KG Machine dimension: 1100x 780x 1200 mm Main body Recovery rate: 85%
C. Operating steps:After opening the crate, plug in 220 V power, and connect the ground (earth). Open the lid and fill the tank up to the level with solvent to be recovered (60 L).Close the lid and tighten it. Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1). Set up the thermostat (18) for example for Perc. Is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure (3) high at 0. 03 Mpa / low at 0. 01mpa, and steam cooling fan thermostat (11) at 40 degree C. Turn on the power switch (15) , steam cooling switch (16) , heater switch (17) and vacuum pump switch (12). If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).
D. Important: Install the unit in a wide and ventilated place. Disconnect electric power before doing any action.No taking off the control panel. Change the diathermic oil every 1000 working hours. No filling the solvent container up over the level (60 liters). Remove the waste after every recovery process.
Other Information
- Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Western Union
- Minimum Order Quantity: 1 Set/Sets
- Port of Dispatch: Ahmedabad
- Production Capacity: 100
- Delivery Time: 4 Weeks
- Packaging Details: Wooden Crates, Export Packaging
| | | | Solvent Recovery 80 LTR  | Special Features Flexo 80L-RHB Solvent Recovery Unit For photopolymer flexo plates
A. General Description: 80L-RHB is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and Cooling can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.
B. Technical information: Recovery volume :80 liters Power consume : 220V 5. 65kw Diathermic oil : 33 KG Machine dimension : 1300x 880x 1300 mm Main body Recovery rate : 85%
C. Operating steps:After opening the crate, plug in 220 V power, and connect the ground (earth). Open the lid and fill the tank up to the level with solvent to be recovered (80 L).Close the lid and tighten it.Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1). Set up the thermostat (18) for example for Perc. Is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure (3) high at 0. 03 Mpa / low at 0. 01mpa, and steam cooling fan thermostat (11) at 40 degree C. Turn on the power switch (15) , steam cooling switch (16) , heater switch (17) and vacuum pump switch (12). If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).
D. Important:Install the unit in a wide and ventilated place. Disconnect electric power before doing any action.No taking off the control panel. Change the diathermic oil every 1000 working hours. No filling the solvent container up over the level (80 liters). Remove the waste after every recovery process.
Other Information
- Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Western Union
- Minimum Order Quantity: 1 Set/Sets
- Port of Dispatch: Ahmedabad
- Production Capacity: 100
- Delivery Time: 4 Weeks
- Packaging Details: Wooden Crates, Export Packaging
| Solvent Recovery 100 LTR  | Special Features Flexo 100L-RHB Solvent Recovery Unit For photopolymer flexo plates
A. General description: 100L-RHB is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.
B. Technical information: Recovery volume :100 liters Power consume : 220V 6. 65kw Diathermic oil : 40 KG Machine dimension : 1500x 980x 1500 mm Main body Recovery rate : 85%
C. Operating steps: After opening the crate, plug in 220 V power, and connect the ground (earth). Open the lid and fill the tank up to the level with solvent to be recovered (100 L).Close the lid and tighten it.Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1). Set up the thermostat (18) for example for Perc. Is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure (3) high at 0. 03 Mpa / low at 0. 01mpa, and steam cooling fan thermostat (11) at 40 degree C. Turn on the power switch (15) , steam cooling switch (16) , heater switch (17) and vacuum pump switch (12). If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).
D. Important: Install the unit in a wide and ventilated place. Disconnect electric power before doing any action.No taking off the control panel. Change the diathermic oil every 1000 working hours. No filling the solvent container up over the level (100 liters). Remove the waste after every recovery process.
Other Information
- Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Western Union
- Minimum Order Quantity: 1 Set/Sets
- Port of Dispatch: Ahmedabad
- Production Capacity: 100
- Delivery Time: 4 Weeks
- Packaging Details: Wooden Crates, Export Packaging
| | | | Solvent Recovery 200 LTR  | Special Features Flexo 200L-RHB Solvent Recovery Unit For photopolymer flexo plates
A. General Description: 200L-RHB is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling, can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.
B. Technical information: Recovery volume: 200 liters Power consume: 380V 10kw Diathermic oil: 80 KG Machine dimension: 2500x 170x 2300 mm Main body Recovery rate: 85%
C. Operating steps: After opening the crate, plug in 220 V power, and connect the ground (earth). Open the lid and fill the tank up to the level with solvent to be recovered (200 L).Close the lid and tighten it.Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1). Set up the thermostat (18) for example for Perc. Is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure (3) high at 0. 03 MPA / low at 0. 01mpa, and steam cooling fan thermostat (11) at 40 degree C. Turn on the power switch (15) , steam cooling switch (16) , heater switch (17) and vacuum pump switch (12). If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).
D. Important:Install the unit in a wide and ventilated place. Disconnect electric power before doing any action.No taking off the control panel. Change the diathermic oil every 1000 working hours. No filling the solvent container up over the level (200 liters). Remove the waste after every recovery process.
Other Information
- Pay Mode Terms: L/C (Letter of Credit), T/T (Bank Transfer), Western Union
- Minimum Order Quantity: 1 Set/Sets
- Port of Dispatch: Ahmedabad
- Production Capacity: 100
- Delivery Time: 4 Weeks
- Packaging Details: Wooden Crates, Export Packaging
|
|